CRNE 10-9 A-FGJ-A-V-HQQV Grundfos99071830

Product name: CRNE 10-9 A-FGJ-A-V-HQQV; Product No: 99071830; Technical ; Pump speed on which pump data are based: 3526 rpm; Rated head: 107.1 m; Maximum head: 133 m; Stages: 9; Impellers: 9; Number of reduced-diameter impellers: 0; Low NPSH: N; Pump orientation: Vertical; Shaft seal arrangement: Single; Code for shaft seal: HQQV; Approvals on nameplate: CE, EAC; Curve tolerance: ISO9906:2012 3B; Pump version: A; Model: A; Materials ; Base: Stainless steel; Base: EN 1.4408; Base: AISI 316; Impeller: Stainless steel; Impeller: EN 1.4401; Impeller: AISI 316; Material code: A; Code for rubber: V; Bearing: SIC; Installation ; Maximum ambient temperature: 50 °C; Max pressure at stated temp: 25 bar / 90 °C; Max pressure at stated temp: 25 bar / -20 °C; Type of connection: DIN / ANSI / JIS; Size of inlet connection: DN 40; Size of outlet connection: DN 40; Pressure rating for connection: PN 25; Flange rating inlet: 300 lb; Flange size for motor: FF265; Connect code: FGJ; Liquid ; Liquid temperature range: -20 .. 90 °C; Selected liquid temperature: 20 °C; Density: 998.2 kg/m³; Electrical data ; Motor standard: IEC; Motor type: 132SE; IE Efficiency class: IE5; Rated power - P2: 5.5 kW; Power (P2) required by pump: 5.5 kW; Rated current: 10.3-8.20 A; Cos phi - power factor: 0.92-0.88; Efficiency: 92.7%; Motor efficiency at full load: 92.7 %; Insulation class (IEC 85): F; Motor protec: YES; Motor No: 98971051; Controls ; Control panel: Standard; Function Module: FM300 - Advanced; Frequency converter: Built-in; Pressure sensor: N; Others ; Minimum efficiency index, MEI ≥: 0.70; DOE Pump Energy Index CL: 0.00; DOE Pump Energy Index VL: 0.00; Gross weight: 112 kg; Shipping volume: 0.37 m³; Config. file no: 99058972

Rated speed
 360-4000 rpm
Maximum operating pressure
 25 bar
Nominal flow
 12.1 m³/h
Media type
 Water
Mains frequency
 50 / 60 Hz
Nominal voltage
 3 x 380-500 V
Degree of protection
 IP55
Customs tariff number
 84137075
Expected origin
 HU
Weight
 83 kg